> DDS Function Signal Generator
> Digital Multimeters
> Distortion Analyzer
> Four Probe experiment
> Function Generator
> IC Testers
> LCR Meters
> Oscilloscopes
> Power Supplies
> Pulse Wave Frequency Meter
> Signal / Function Generator
> Storage Oscilloscopes
> Two Probe Setup
> Withstand Tester
> General Physics Equipments
> TEKON INSTRUMENTS
  - T100 Network Cable Detector
  - T550 Power Quality Analyzer
  - T560 Power Quality Analyzer
  - T600 Txr Turn to Ration
  - T610 Txr Analyzer
  - T650 ESS Diagnostic
  - T700 Ind. Robot Diagnostic
  - T800 EV-HEV Diagonstic
 
   
   
   
   
   
   
   
   
 
Multi Function Tester

Multi Function Tester

Hipot Tester

Ground Bond Tester

4000 Series ( 4 in 1 ) - AC/DC Hipot, Insulation and Ground Bond Tester
 
The 4000 Series provides advanced 4-in-1 test capability in a convenient one-box solution. Our most popular multi-function tester, the 4000 Series performs AC Hipot, DC Hipot, Insulation Resistance and Ground Bond tests while taking up minimal production line space. The 4000 Series includes the most intuitive menu system in the industry, reducing setup time and increasing production line throughput for any application. With multiple memories and an optional RS-232 interface, you can quickly perform tests on a variety of DUT’s from the front panel or with a PC. Choose from two models.
Relevant Applications: • Appliance • Cable • Motors & Pumps
 
Features:
• Versatile 4-in-1 functionality
• Intuitive user interface
• Meets 200 mA short circuit requirements
• 6 programmable memories with 6 test steps each
• Automate with PLC control or optional RS-232 interface
• Remote Safety Interlock
 
 
4320 & 4520: MULTI-FUNCTION ELECTRICAL SAFETY TESTER
 
Specifications 4320 4520
Input
Voltage 115/230V AC ± 10%, User Selection 115/230V AC Auto Range, ± 15% variation
Frequency 50/60 Hz ±5% 50/60 Hz ±5%
Fuse 6.3A 250V Slow blow 15A 250V Slow blow
Dielectric Withstand Test mode
Output Rating 5 kV @ 20 mAAC 5 kV @ 100 mAAC
  6 kV @ 5 mADC 6 kV @ 10 mADC
Voltage Setting
- Range 0.00 - 5.00 kVAC 0.00 - 5.00 kVAC
  0.00 - 6.00 kVDC 0.00 - 6.00 kVDC
- Resolution 0.01 kV 0.01 kV
- Accuracy ± (2% of setting + 5 volts) ± (2% of setting + 5 volts)
Voltage Display
- Range 0.00 - 5.00 kVAC 0.00 - 5.00 kVAC
  0.00 - 6.00 kVDC 0.00 - 6.00 kVDC
- Resolution 0.01 kV 0.01 kV
- Accuracy ± (2% of reading + 10 volts) ± (2% of reading + 10 volts)
Current Display
- Range 0.00 - 20.00 mAAC 0.00 – 99.99 mAAC
  0.00 - 5.00 mADC 0.00 – 10.00 mADC
- Resolution 0.01 mA 0.01 mA
- Accuracy ± (2% of reading + 0.02 mA) ± (2 % of reading + 0.06 mA)
Hi - Lo Limit AC
- Range 0.00 - 20.00 mA 0.00 – 99.99 mAAC
- Resolution 0.01 mA 0.01 mA
- Accuracy ± (2% of setting + 0.02 mA) (2 % of reading + 0.06 mA)
Hi - Lo Limit DC
- Range 0.00 - 5.00 mA 0.00 – 10.00 mADC
- Resolution 0.01 mA 0.01 mA
- Accuracy ± (2% of setting + 0.02 mA) (2 % of reading + 0.06 mA)
     
Failure Detector Audible and Visual Audible and Visual
DC Output Ripple < 5% at 6 kVDC @ 5 mA, resistive load ≤ 5% Ripple RMS at 6 KVDC @ 10 mA, resistive load
Discharge Time ≤ 200 ms ≤ 200 ms
Max. Capacitive Load in DC Mode
- 1.00 uF < 1 kV < 1 kV
- 0.75 uF < 2 kV < 2 kV
- 0.50 uF < 3 kV < 3 kV
- 0.08 uF < 4 kV < 4 kV
- 0.04 uF < 5 kV < 5 kV
- 0.01 uF < 6 kV < 6 kV
     
AC Wave Form Sine Wave, Crest Factor = 1.3 – 1.5 Sine Wave, Crest Factor = 1.3 – 1.5
AC Output Frequency (Range) 60 or 50 Hz, user selection 60 or 50 Hz, user selection
Output Regulation ± (1 % of setting + 5 volts) from no load to full load ± (1 % of setting + 5 volts) from no load to full load
Dwell Timer
- Range 0, 0.2 - 999.9 sec (0 = continuous) 0, 0.2 - 999.9 sec (0 = continuous)
- Resolution 0.1 sec increments 0.1 sec increments
- Accuracry ± (0.1% + 0.05 sec) ± (0.1% + 0.05 sec)
Ramp Timer    
- Range 0.1 – 999.9 sec 0.1 – 999.9 sec
- Resolution 0.1 sec increments 0.1 sec increments
- Accuracry ± (0.1% + 0.05 sec) ± (0.1% + 0.05 sec)
     
Insulation Resistance Test Mode
Output Voltage    
- Range 100 – 1000 Volts DC 100 – 1000 Volts DC
- Resolution 1 volt 1 volt
- Accuracry ± (2% of reading + 5 volts) ± (2% of reading + 5 volts)
Voltage Display    
- Range 0 – 1000 V 0 – 1000 V
- Resolution 1 volt 1 volt
- Accuracry ± (2% of reading + 2 counts) ± (2% of reading + 2 counts)
Resistance Display    
- Range 1 - 1000 MΩ (4 digit, auto ranging) 1 - 1000 MΩ (4 digit, auto ranging)
- Resolution 500VDC, 0.01MΩ 1.00–40.00 1.00–40.00
- Resolution 500VDC, 0.1MΩ 35.0–999.9 35.0–999.9
- Resolution 1000VDC, 0.01MΩ 1.00–80.00 1.00–80.00
- Resolution 1000VDC, 0.1MΩ 75.0–999.9 75.0–999.9
HI-Limit Range 0, 1 – 1000 MΩ (0 = off) 0, 1 – 1000 MΩ (0 = off)
LO-Limit Range 1 – 1000 MΩ 1 – 1000 MΩ
  0, 0.5 - 999.9 sec (0 = constant) 0, 0.5 - 999.9 sec (0 = constant)
Delay Timer    
- Resolution 0.1 sec 0.1 sec
- Accuracy ± (0.1% + 0.05 sec) ± (0.1% + 0.05 sec)
     
Ground Bond Test Mode
Output Voltage Range 6 VAC fixed 6 VAC fixed
Output Frequency Range 60 or 50 Hz, user selectable 60 or 50 Hz, user selectable
Output Current
- Range 0.1 Amp 0.1 Amp
- Resolution ± (2 % of setting + 0.02 A) ± (2 % of setting + 0.02 A)
- Accuracry 0.0 – 30.0 Amps 0.0 – 30.0 Amps
Current Display
- Range 0.0 – 30.0 Amps 0.0 – 30.0 Amps
- Resolution 0.1 Amp 0.1 Amp
- Accuracry ± (3 % of reading + 0.1 A) ± (3 % of reading + 0.1 A)
HI-Limit LO-Limit
- Range 0 – 510 mΩ for 3.0 – 10.0 Amps 0 – 510 mΩ for 3.0 – 10.0 Amps
  0 – 200 mΩ for 10.1 – 25.0 Amps 0 – 200 mΩ for 10.1 – 25.0 Amps
  0 – 150 mΩ for 25.1 – 30.0 Amps 0 – 150 mΩ for 25.1 – 30.0 Amps
- Resolution 1 mΩ 1 mΩ
- Accuracy ± (2 % of setting + 2 mΩ) ± (2 % of setting + 2 mΩ)
Dwell Timer
- Range 0, 0.5 - 999.9 sec (0 = constant) 0, 0.5 - 999.9 sec (0 = constant)
- Resolution 0.1 sec 0.1 sec
- Accuracry ± (0.1% + 0.05 sec) ± (0.1% + 0.05 sec)
Milliohm Offset
- Max. Offset Capability: 100 mΩ 100 mΩ
- Resolution 1 mΩ 1 mΩ
- Accuracy ± (2 % of setting + 2 mΩ) ± (2 % of setting + 2 mΩ)
     
General Specifications
PLC Remote Control Inputs – test, reset, interlock & recall memory 1–6
Outputs – pass, fail, test-in-process
Memory Allows storage of up to 6 different test programs and 6 steps per memory and a single step mode
Interface Optional RS-232 interface
Security Lockout capability to avoid unauthorized access to test set-up programs
Calibration Software & adjustments made through front panel
Mechanical Bench or rack mount with tilt up front feet
Dimensions (W x H x D) 11” x 3.5” x 17” (280 x 89 x 430 mm) 16.9” x 5.2” x 15.7” (430 x 133 x 400 mm)
Weight 33 lbs. (15 kg) 54 lbs. (24.5 Kg)
   
Supplied Accessories  
102-050-913 High Voltage Probe (6 ft.)
102-055-913 Input Voltage Clip (6 ft.)
125-013-001 Input Power Cable (6 ft.) (4320)
99-10164-01 Input Power Cable (6 ft.) (4520)
99-10008-01 High Current Return Lead
99-10009-01 High Current Output Lead
99-10040-01 Interlock
99-10106-01 Fuse (4320)
99-10656-01 Fuse (4520)
 
6000 Series ( 6 in 1 ) AC/DC Hipot, Insulation, Functional Run, Line Leakage & Ground Bond Tester
 
6330 MULTI-FUNCTION ELECTRICAL SAFETY TESTER
 
The 6330 is our most advanced multi-function electrical safety tester with 6-in-1 test capability. Our flagship model is designed to make advanced testing applications simple with the most intuitive user interface on the market. With minimal setup time, you can perform AC Hipot, DC Hipot, Ground Bond, Insulation Resistance, Functional Run and Line Leakage tests on a variety of DUT’s. The 6330 maximizes
production line throughput far beyond a single function instrument, while taking up less space. Use the 6330 from the front panel or automate your testing via the RS-232 interface.
 
Relevant Applications: • Medical • Appliance • Motors & Pumps • Information Technology
 
Features:
• Versatile 6-in-1 functionality
• Intuitive user interface
• 4 built-in NRTL-compliant measuring devices
• 10 programmable memories with 20 test steps each
• Automate with PLC control or RS-232 interface
• Remote Safety Interlock
Specifications 6330
Input
Voltage 115/230V AC selectable, ± 10% variation
Frequency 50/60 Hz ±5%
Fuse 6.3A 250V Slow blow
Dielectric Withstand Test mode
Output Rating 3.5 kV @ 30 mAAC
  4.0 kV @ 5 mADC
Voltage Setting
- Range 0.00 - 3.50 kVAC
  0.00 - 4.00 kVDC
- Resolution 0.01 kV
- Accuracy ± (2% of setting + 5 volts)
Current Display
- Range 0.00 - 30.00 mAAC
  0.00 - 5.00 mADC
- Accuracy ± (2% of reading + 0.02 mA)
Hi - Lo Limit AC
- Range 0.00 - 30.00 mA
- Accuracy ± (2% of setting + 0.02 mA)
Hi - Lo Limit DC
- Range 0.00 - 5.00 mA
- Accuracy ± (2% of setting + 0.02 mA)
   
Failure Detector Audible and Visual
DC Output Ripple < 5% at 6 kVDC @ 5 mA, resistive load
Discharge Time ≤ 200 ms
Max. Capacitive Load in DC Mode
- 1.00 uF < 1 kV
- 0.75 uF < 2 kV
- 0.50 uF < 3 kV
- 0.08 uF < 4 kV
   
AC Wave Form Sine Wave, Crest Factor = 1.3 – 1.5
AC Output Frequency 60 or 50 Hz, user selection
Output Regulation ± (1 % of setting + 5 volts) from no load to full load
 
Dwell Timer 0, 0.2 - 999.9 sec (0 = continuous)
Ramp Timer 0.1 – 999.9 sec
   
Insulation Resistance Test Mode
Output Voltage  
- Range 100 – 1000 Volts DC
- Accuracry ± (2% of reading + 5 volts)
Resistance Display  
- Range 1 - 1000 MΩ (4 digit, auto ranging)
- Resolution 500VDC, 0.01MΩ 1.00–40.00
- Resolution 500VDC, 0.1MΩ 35.0–999.9
- Resolution 1000VDC, 0.01MΩ 1.00–80.00
- Resolution 1000VDC, 0.1MΩ 75.0–999.9
HI/LO -Limit - Range 1 – 1000 MΩ (0 = off)
Delay Timer - Range 0, 0.5 - 999.9 sec (0 = constant)
   
Ground Bond Test Mode
Output Voltage 6 VAC fixed
Output Frequency 60 or 50 Hz, user selectable
Output Current 3.0 - 30.0A AC
Current Display 0.0 – 30.0 Amps
HI-Limit LO-Limit
- Range 0 – 510 mΩ for 3.0 – 10.0 Amps
  0 – 200 mΩ for 10.1 – 25.0 Amps
  0 – 150 mΩ for 25.1 – 30.0 Amps
- Accuracy ± (2 % of setting + 2 mΩ)
 
Dwell Timer 0, 0.5 - 999.9 sec (0 = constant)
Milliohm Offset
- Range 0 - 100 mΩ
- Accuracy ± (2 % of setting + 2 mΩ)
   
Run Test Mode
DUT Power
- Voltage 0 - 277 VAC Single Phase Unbalanced
  0 - 30 A maximum
- Current 30 AAC max continuous
Voltage Display 0.0 – 277.0 VAC Full Scale
Short Circuit Protection
- Short Circuit Current 50A < 3s
- Inrush current 180A
- Response time 10 μs
Delay Time Setting 0.2 - 999.9 seconds
Dwell Time Setting 0, 0.1 - 999.9 seconds (0 = continuous)
Timer Display 0.0 - 999.9 seconds
TRIP POINTS
- Voltage 0.0 - 277.0 VAC
- Current 0.0 - 30.0 AAC
- Watts 0 - 8400 Ω
- Power Factor 0.000 - 1.000
- Leakage Current 0.00 - 10.00 mA (0 = off)
  Leakage current measuring resistor MD=2KΩ ± 1%
   
Line Leakage Test Mode
DUT Power  
- Voltage 0 - 277 VAC Single Phase Unbalanced
  0 - 30 A maximum
- Current 30 AAC max continuous
Voltage Display 0.0 - 277.0 VAC Full Scale
Short Circuit Protection
- Short circuit current 50 A < 3 s
- Inrush current 180A
- Response time 10 μs
Leakage Current (RMS Only)
- Range 0.0 μA - 6000 μA
- Accuracy 15 to 100 kHz ± (2% of reading + 3 μA)
- DC >100 k to 1 MHz ± 5% of reading
Measuring Device
- A UL544 Non Patient
- B IEC60990 Fig4-U2
- C UL2601-1, UL60601-1
- F Frequency Check, External MD (1k Ω)
- X External MD (1k Ω)
   
Line Condition Neutral, Reverse, Ground
Probe G – L
HI-Limit / LO-limit 0 – 6000 μA
Delay Timer 0, 1.0 – 999.9 sec (0 = continuous)
General Specifications
PLC Remote Control Inputs – test, reset, interlock & recall memory 1–6
Outputs – pass, fail, test-in-process
Memory 10 memories with 20 steps per memory
Interface RS-232 interface
Security Key lock and memory lock capability to avoid unauthorized access
Terminations 6’ (1.80 m) high voltage and (2) return leads w/clips.
Calibration Software & adjustments made through front panel
Mechanical Bench or rack mount with tilt up front feet
Environmental
- Operating temperature 32º - 104º F (0º - 40º C)
- Relative Humidity 0 - 80%
Dimensions (W x H x D) 16.9” x 5.2” x 19.6” (430 x 133 x 500 mm)
Weight 48.5 lbs. (22 kg)
   
Supplied Accessories  
102-055-913 High Voltage Lead (6 ft.)
125-013-001 Input Power Cable (6 ft.)
99-10457-01 Cable Assembly High Current Lead
99-10468-01 Cable Assembly Ground Lead
99-10009-01 High Current Output Lead
99-10008-01 High Current Return Lead
99-10469-01 LLT DUT Input Cable LINE
99-10470-01 LLT DUT Input Cable NEUTRAL
99-10471-01 LLT DUT HV Output Cable LINE
99-10472-01 LLT DUT HV Output Cable NEUTRAL
99-10040-01 Interlock